Evaluation of 1-phase, 3-phase and Lightning Faults on Wind Farms using EMTP-RV
- Department of Electrical Engineering, Urmia University, Urmia, Iran
Published in Issue 2024-02-21
How to Cite
Arabi Nowdeh, S., Chitsaz, M., & Khanabdal, S. (2024). Evaluation of 1-phase, 3-phase and Lightning Faults on Wind Farms using EMTP-RV. Majlesi Journal of Electrical Engineering, 8(1). https://oiccpress.com/mjee/article/view/5268
HTML views: 17
Abstract
Since development of wind power plants installation is growing, problems related to network connecting, stability and voltage effects become more important. On the other hand, wind farms are often open to lightning because of their long height and specific appearance. In this paper modeling and simulation of 1-phase, 3-phase and lightning faults in a wind farm consisting of 40 wind turbines and faults impact on wind farm and the network is investigated in EMTP-RV environment. In this field itâs necessary to develop a precise modeling out of wind power plant in order to evaluate the effects of these power plants on dynamical behavior of the power system. These models can be used in designing new protection systems, new protection algorithms, and new strategies for power plants exploitation improvement. Each wind unit in the farm is connected to the whole units connected to the network using a doubly fed induction generator (DFIG).تÙÛÛÙ 1-اÙÙØ±ØÙØ©Ø 3-اÙÙØ±ØÙØ© ÙØ§ÙØ¨Ø±Ù Ø§ÙØ¹ÛÙØ¨ ÙÛ ÙØ²Ø§Ø±Ø¹ Ø§ÙØ±ÛØ§Ø Ø¨Ø§Ø³ØªØ®Ø¯Ø§Ù ØªØ¯Ø§Ø±Ø³ خاصة-RVÙÙØ° تطÙÛØ± Ø·Ø§ÙØ© Ø§ÙØ±ÛØ§Ø ØªØ±Ú©ÛØ¨ اÙÙØ¨Ø§ØªØ§Øª تÙÙÙØ اÙÙØ´Ø§Ú©Ù اÙÙØªØ¹ÙÙØ© شبکة Ø§ÙØ§ØªØµØ§ÙØ ØªØµØ¨Ø Ø§ÙØ§Ø³ØªÙرار ÙØ§ÙØ¬ÙØ¯ آثار أکثر Ø£ÙÙÛØ©. ÙÙ ÙØ§ØÛØ© Ø£Ø®Ø±ÙØ ÙØ²Ø§Ø±Ø¹ Ø§ÙØ±ÛØ§Ø ØºØ§ÙØ¨Ø§ ÙØ§ تکÙÙ ÙÙØªÙØØ© Ø¥ÙÙ Ø§ÙØ¨Ø±Ù بسبب Ø·ÙÙÙÙ Ø·ÙÛÙØ© ÙÙØ¸Ùر ÙØ¹ÛÙ. ÙÛ ÙØ°Ù اÙÙÙØ°Ø¬Ø© ÙØ§ÙÙØØ§Ú©Ø§Ø© ÙØ±ÙØ© ÙÙ Ø§ÙØ¹ÛÙØ¨ 1-اÙÙØ±ØÙØ©Ø 3-ÙØ±ØÙØ© ÙØ§Ùبر٠ÙÛ ÙØ²Ø±Ø¹Ø© Ø§ÙØ±ÛØ§Ø Ø§ÙØªÛ تتکÙÙ ÙÙ 40 ØªÙØ±Ø¨ÛÙØ§Øª Ø§ÙØ±ÛØ§Ø ÙØ£Ø®Ø·Ø§Ø¡ ØªØ£Ø«ÛØ± عÙÙ ÙØ²Ø±Ø¹Ø© Ø§ÙØ±ÛØ§Ø ÙØ§Ùشبکة ÙÛØ¬Ø±Û Ø§ÙØªØÙÛÙ ÙÛ Ø§ÙØ¨Ûئة تدارس خاصة-RV. ÙÛ ÙØ°Ø§ اÙÙØ¬Ø§Ù ÙÙ Ø§ÙØ¶Ø±ÙØ±Û ØªØ·ÙÛØ± ÙÙØ§Ø°Ø¬ دÙÛÙØ© ÙÙ ÙØØ·Ø© ÙØ·Ø§ÙØ© Ø§ÙØ±ÛØ§Ø Ù٠أج٠تÙÛÛ٠آثار ÙØ°Ù اÙÙØØ·Ø§Øª عÙÙ Ø§ÙØ³ÙÙÚ© Ø§ÙØ¯ÛÙØ§ÙÛÚ©Û ÙÙÙØ¸Ø§Ù Ø§ÙØ·Ø§ÙØ©. ÙØ°Ù اÙÙÙØ§Ø°Ø¬ ÛÙک٠استخداÙÙØ§ ÙÛ ØªØµÙÛÙ ÙØ¸Ù Ø¬Ø¯ÛØ¯Ø© ÙÙØÙØ§ÛØ©Ø Ø®ÙØ§Ø±Ø²ÙÛØ§Øª Ø¬Ø¯ÛØ¯Ø© ÙÙØÙØ§ÛØ©Ø ÙØ§Ø³ØªØ±Ø§ØªÛØ¬ÛØ§Øª Ø¬Ø¯ÛØ¯Ø© ÙØªØØ³ÛÙ ÙØØ·Ø§Øª Ø§ÙØ·Ø§ÙØ© Ø§ÙØ§Ø³ØªØºÙاÙ. ÛØªÙ ØªÙØµÛÙ Ú©Ù ÙØØ¯Ø© Ø§ÙØ±ÛØ§Ø ÙÛ Ø§ÙÙØ²Ø±Ø¹Ø© Ø¥ÙÙ ÙØØ¯Ø§Øª کاÙÙØ© ÙØªØµÙØ© Ø¨Ø§ÙØ´Ø¨Ú©Ø© باستخدا٠ÙÙÙØ¯ Ø§ÙØØ« ØªØºØ°ÛØ© ÙØ¶Ø§Ø¹ÙØ© (DFIG). è¯ä»·ä¸çåç¸ï¼ä¸ç¸åé·å»äºæé£çµåºä½¿ç¨EMTP-RVååé¿ææ¯zï¼è¨å¸åé¿åæå·æ±æ½è±¡ç±äºé£ååçµåå®è£çåå±ç䏿å¢é¿ï¼å¯¹ç½ç»è¿æ¥ç¸å³çé®é¢ï¼ç¨³å®æ§åçµåçå½±åå徿´å éè¦ãå¦ä¸æ¹é¢ï¼é£çµåºï¼å 为å®ä»¬çé¿çé«åº¦åç¹å®å¤å½¢ç常å¼é·å»ãæ¬æå»ºæ¨¡çåç¸ï¼3ç¸åé·å»äºææ¨¡æä¸ä¸ªé£çµåºåæ¬é£çµåº40çé£åæ¶¡è½®æºåæéå½±åï¼å¹¶å¨ç½ç»ä¸çEMTP-RVç¯å¢è¿è¡äºç ç©¶ãå¨è¿ä¸é¢åæå¿è¦å¼åä¸ä¸ªç²¾ç¡®ç建模äºé£ååçµåçï¼ä»¥ä¾¿è¯ä¼°è¿äºåçµå对çµåç³»ç»çå¨åå¦è¡ä¸ºçå½±åãè¿äºæ¨¡åå¯ä»¥å¨è®¾è®¡æ°çä¿æ¤ç³»ç»ï¼ä¿æ¤æ°ç®æ³ï¼å¹¶ä¸ºçµåå©ç¨æ¹è¿çæ°æç¥ä¸ãåºä¸çæ¯ä¸ªé£åååè¢«è¿æ¥å°è¿æ¥å°ä½¿ç¨å馿åºåçµæºï¼DFIGï¼ç½ç»çæ´ä½ååãKeywords
- 3-phase Fault,
- lightning. EMTP-RV,
- Transient State,
- Wind farm