Recently applications of multilevel inverter become more convenient in power electronic. The Output closes to sinusoidal wave form, capability of creating high value of voltage or current, less blocking voltage on switches andâ¦, made multilevel inverter popular in more application. There are several type of multilevel converter such as: neutral point diode clamped, fly capacitor and cascade H-Bridge. The cascade H-bridge inverter (CHB) is very popular then other multilevel inverter because its control is very simple in compare with others. The new approach of seven levels Space vector modulation (SVM) is utilized to produce required fundamental voltage in CHB. Cat swarm optimization (CSO) is introduced as a new meta heuristic algorithm to minimize total harmonic distortion (THD), switching parameters tuned and this value has been compared with arbitrary values. The simulation results have been carried out using MATLAB/SIMULINK Software

Keywords

  • Cascade H-Bridge inverter (CHB),
  • Cat Swarm Optimization (CSO),
  • Space vector Modulation (SVM),
  • Total Harmonic Distortion THD