Industrial application of apodized gas sensor for on-line and in situ measurement of CO and CO2 concentration
Abstract
AbstractThe performance of an apodized gas sensor is demonstrated through simultaneous detection of CO and CO2 absorption lines around 1.57 µm in the recuperator channel of a gas-fired industrial furnace at Shahid Montazeri power plant (SMPP) industry. This led to the concentration measurement of targeted molecules as less thanâ~â1% and 9.5%, respectively, at atmospheric pressure and 350 °C, indicating close consistency with the reference data reported by SMPP. A minimum detectable absorption ofâ~â0.4âÃâ10â3, corresponding to a detection sensitivity ofâ~â4.8âÃâ10â9 cmâ1 Hzâ1/2 is measured in this application.
Keywords
- Apodized gas sensor,
- Tunable diode laser,
- Wavelength modulation spectroscopy
10.1007/s40094-020-00396-z