10.1007/s40097-014-0102-5

Electrochemical detection of l-serine and l-phenylalanine at bamboo charcoal–carbon nanosphere electrode

  1. Department of Chemistry, National Institute of Technology, Agartala, Tripura, 799055, IN
Cover Image

Published in Issue 23-04-2014

How to Cite

Saha, M., & Das, S. (2014). Electrochemical detection of l-serine and l-phenylalanine at bamboo charcoal–carbon nanosphere electrode. Journal of Nanostructure in Chemistry, 4(2 (June 2014). https://doi.org/10.1007/s40097-014-0102-5

HTML views: 36

PDF views: 115

Abstract

Abstract A carbon nanosphere electrode (CN) has been fabricated for the electrochemical detection of l -serine and l -phenylalanine. Electrochemical behavior of amino acids was investigated using cyclic voltammetry, differential pulse voltammetry, square wave voltammetry and linear sweep voltammetry. In optimal conditions, the peak current of both amino acids on the CN electrode was found to enhance greatly. A sensitive oxidation peak at 0.085 V was observed in the determination of l -serine and 0.06 V for l -phenylalanine. A linearity between the oxidation peak current and the concentration of both amino acids was obtained in the range of 1–100 µM ( R 2  = 0.99783 for l -serine, 0.99618 for l -phenylalanine). The practical application of the carbon nanosphere electrode in the determination of the amino acids possesses high selectivity, sensitivity and stability.

Keywords

  • Carbon nanospheres,
  • l-Serine,
  • l-Phenylalanine

References

  1. Elsila et al. (2007) Mechanisms of amino acid formation in interstellar ice analogs (pp. 911-918) https://doi.org/10.1086/513141
  2. deKoning et al. (2003) l-serine in disease and development (pp. 653-661) https://doi.org/10.1042/bj20021785
  3. Mortell et al. (2006) Structure–activity relationships of α-amino acid ligands for the α2δ subunit of voltage-gated calcium channels 16(5) (pp. 1138-1141) https://doi.org/10.1016/j.bmcl.2005.11.108
  4. Nelson and Cox (2000) Worth Publishing
  5. Heftmann (1992) Elsevier
  6. Li et al. (2001) Electrochemical and FTIR studies of l-phenylalanine adsorption at the Au(111) electrode (pp. 299-310) https://doi.org/10.1016/S0022-0728(00)00391-0
  7. Grudpan and Kamfoo (1999) Flow injection dialysis for the determination of anions using ion chromatography (pp. 1023-1026) https://doi.org/10.1016/S0039-9140(99)00047-8
  8. Alwarthan (1993) Determination of ascorbic-acid by flow-injection with chemiluminescence detection (pp. 639-642) https://doi.org/10.1039/an9931800639
  9. Agater and Jewsbury (1997) Direct chemiluminescence determination of ascorbic acid using flow injection analysis (pp. 289-294) https://doi.org/10.1016/S0003-2670(97)00556-4
  10. Keyvanfard et al. (2013) Highly selective and sensitive voltammetric sensor based on modified multiwall carbon nanotube paste electrode for simultaneous determination of ascorbic acid, acetaminophen and tryptophan (pp. 811-816) https://doi.org/10.1016/j.msec.2012.11.005
  11. Daud et al. (2012) Electrochemical sensor for As(III) utilizing CNTs/leucine/nafion modified electrode (pp. 175-185)
  12. Akhtar et al. (1997) Detection of amino acids at conducting electroactive polymer modified electrodes using flow injection analysis. Part II. Use of microelectrodes (pp. 211-223) https://doi.org/10.1016/S0003-2670(96)00478-3
  13. Li et al. (1995) Electrocatalytic oxidation and flow detection of cysteine at an aquocobalamin adsorbed glassy carbon electrode (pp. 885-888) https://doi.org/10.1016/0039-9140(95)01502-3
  14. Tony et al. (2013) Multi-walled carbon nanotube modified carbon paste electrode as an electrochemical sensor for the determination of epinephrine in the presence of ascorbic acid and uric acid (pp. 3294-3302) https://doi.org/10.1016/j.msec.2013.04.010
  15. Das and Saha (2013) Non enzymatic electrochemical detection of glucose at rice starch-nanoparticles modified electrode (pp. 967-975)
  16. Das and Saha (2013) Preparation of carbon nanosphere from bamboo and its use in water purification (pp. 174-177)
  17. Das and Saha (2013) Electrochemical studies of carbon nanotube obtained from coconut oil as non enzymatic glucose biosensor (pp. 645-648) https://doi.org/10.1166/asem.2013.1349
  18. Sonkar et al. (2010) Carbon nanocubes and nanobricks from pyrolysis of rice (pp. 1-4) https://doi.org/10.1166/jnn.2010.1484
  19. Saha and Das (2014) Fabrication of a nonenzymatic cholesterol biosensor using carbon nanotubes from coconut oil (pp. 94-102) https://doi.org/10.1007/s40097-014-0094-1
  20. Heines (1958) Peter Griess discoverer of diazo compounds (pp. 187-191) https://doi.org/10.1021/ed035p187
  21. Swartz and Krull (1997) Marcel Dekkar
  22. Tian et al. (2013) Nonenzymatic glucose sensor based on nickel ion implanted-modified indium tin oxide electrode (pp. 285-290) https://doi.org/10.1016/j.electacta.2013.02.096
  23. Dar et al. (2012) Ce doped ZnO nanorods for the detection of hazardous chemical (pp. 72-75) https://doi.org/10.1016/j.snb.2012.06.001