10.1007/s40097-022-00489-y

Hydroxyapatite nanoparticles/polyimide-coated platinum electrodes for improved heat-insulating and heavy metal ion diffusion properties

  1. School of Chemistry and Chemical Engineering, Henan Institute of Science and Technology, Xinxiang, Henan, 453003, CN
  2. Department of Urology, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, CN
  3. School of Life Science and Food Engineering, Huaiyin Institute of Technology, Huaian, 223003, CN

Published in Issue 10-03-2022

How to Cite

Wang, H.-J., Yang, G.-G., Zhang, J.-M., Li, S.-M., & Bilal, M. (2022). Hydroxyapatite nanoparticles/polyimide-coated platinum electrodes for improved heat-insulating and heavy metal ion diffusion properties. Journal of Nanostructure in Chemistry, 13(6 (December 2023). https://doi.org/10.1007/s40097-022-00489-y

Abstract

Abstract Polyimide is a promising shell polymer for platinum electrodes because of good biocompatibility, excellent corrosion resistance, mechanical, thermal and chemical stabilities. Herein, hydroxyapatite (HAP) nanoparticles were coated on polyimide encapsulated platinum electrodes to overcome the adverse effects of electrical stimulation. SEM, TEM, XRD and EDS analyses indicated that the coating was homogeneous and dense consisting of nano-hydroxyapatite. The HAP/polyimide coating presented good stability under the conditions of moist heat, high temperature or high shear stress (10 dyn/cm 2 ). Differential thermal analysis revealed that the nano-hydroxyapatite coating could significantly reduce the thermal diffusion from electrical stimulation its thermal elimination rate was about 96 times and 310 times smaller than that of polyimide encapsulated platinum electrode and bare platinum electrode, respectively. Atomic absorption spectroscopy measurement showed that the nano-hydroxyapatite coatings could prohibit the diffusion of platinum ions caused by electrical stimulation. CCK-8 test, neutral red uptake measurement and Tunel analysis revealed that the nano-hydroxyapatite coating could significantly attenuate the cytotoxicity of heavy metal ion from long-term stimulation. The in vivo biocompatibility evaluation by H&E measurement in a rabbit subcutaneous implantation model clearly showed that the nano-hydroxyapatite coating had good tissue response in 6 months. All these data supported that the nano-hydroxyapatite coating improved the biocompatibility of platinum electrodes by prohibiting thermal injury and heavy metal ions diffusion.

Keywords

  • Nano-hydroxyapatite,
  • Polyimide encapsualiton,
  • Biomedical materials,
  • Platinum electrode,
  • Thermal injury,
  • Heavy metal ions diffusion

References

  1. Su et al. (2016) A wireless 32-channel implantable bidirectional brain machine interface 16(10) https://doi.org/10.3390/s16101582
  2. Baek et al. (2020) Fabrication and evaluation of cyclic olefin copolymer-based implantable neural electrode 67(9) (pp. 2542-2551) https://doi.org/10.1109/TBME.2020.2963992
  3. Feiner and Dvir (2018) Tissue-electronics interfaces: from implantable devices to engineered tissues https://doi.org/10.1038/natrevmats.2017.76
  4. Agren et al. (2020) Pulse width and implantable pulse generator longevity in pallidal deep brain stimulation for dystonia: a population-based comparative effectiveness study 98(5) (pp. 331-336) https://doi.org/10.1159/000508794
  5. Suaning et al. (2003) Fabrication of platinum spherical electrodes in an intra-ocular prosthesis using high-energy electrical discharge (pp. 155-161) https://doi.org/10.1016/j.sna.2003.07.002
  6. Lee et al. (2016) Characterization of nerve-cuff electrode interface for biocompatible and chronic stimulating application (pp. 924-934) https://doi.org/10.1016/j.snb.2016.06.169
  7. McDonald (1999) Repairing the damaged spinal cord 281(3) (pp. 64-73) https://doi.org/10.1038/scientificamerican0999-64
  8. Schlosshauer et al. (2001) Towards micro electrode implants: in vitro guidance of rat spinal cord neurites through polyimide sieves by Schwann cells 903(1–2) (pp. 237-241) https://doi.org/10.1016/S0006-8993(01)02391-5
  9. Humayun et al. (1999) Pattern electrical stimulation of the human retina 39(15) (pp. 2569-2576) https://doi.org/10.1016/S0042-6989(99)00052-8
  10. He et al. (2020) Ultraflexible neural electrodes for long-lasting intracortical recording 23(8) https://doi.org/10.1016/j.isci.2020.101387
  11. Jang et al. (2019) A 3D microscaffold cochlear electrode for steroid elution 8(20) https://doi.org/10.1002/adhm.201900379
  12. Keiler et al. (2017) Neointimal fibrotic lead encapsulation-clinical challenges and demands for implantable cardiac electronic devices (pp. 7-17) https://doi.org/10.1016/j.jjcc.2017.01.011
  13. Hibbert et al. (2000) Mass changes and dissolution of platinum during electrical stimulation in artificial perilymph solution 21(21) (pp. 2177-2182) https://doi.org/10.1016/S0142-9612(00)00146-0
  14. de Haro et al. (2002) Electrochemical platinum coatings for improving performance of implantable microelectrode arrays 23(23) (pp. 4515-4521) https://doi.org/10.1016/S0142-9612(02)00195-3
  15. Widge et al. (2007) Self-assembled monolayers of polythiophene conductive polymers improve biocompatibility and electrical impedance of neural electrodes 22(8) (pp. 1723-1732) https://doi.org/10.1016/j.bios.2006.08.011
  16. Mailley et al. (2004) Thin film platinum cuff electrodes for neurostimulation: in vitro approach of safe neurostimulation parameters 63(1–2) (pp. 359-364) https://doi.org/10.1016/j.bioelechem.2003.10.033
  17. Lin et al. (2020) Biocompatibility and bio-insulation of implantable electrode prosthesis ameliorated by A-174 silane primed parylene-C deposited embedment 11(12) https://doi.org/10.3390/mi11121064
  18. Lacour et al. (2008) Polyimide micro-channel arrays for peripheral nerve regenerative implants 147(2) (pp. 456-463) https://doi.org/10.1016/j.sna.2008.05.031
  19. Fukuzawa et al. (2003) Electrical breakdown of ultra-thin polyimide langmuir-blodgett films under a needle-plane electrode system (pp. 243-247) https://doi.org/10.1016/S0040-6090(03)00789-2
  20. Andreeva et al. (2007) Novel type of self-assembled polyamide and polyimide nanoengineered shells-fabrication of microcontainers with shielding properties 23(17) (pp. 9031-9036) https://doi.org/10.1021/la700958h
  21. Richardson et al. (1993) Polyimides as biomaterials: preliminary biocompatibility testing 14(8) (pp. 627-635) https://doi.org/10.1016/0142-9612(93)90183-3
  22. Lago et al. (2005) Long term assessment of axonal regeneration through polyimide regenerative electrodes to interface the pheripheral nerve 26(14) (pp. 2021-2031) https://doi.org/10.1016/j.biomaterials.2004.06.025
  23. Seo et al. (2004) Biocompatibility of polyimide microelectrode array for retinal stimulation (pp. 185-189) https://doi.org/10.1016/j.msec.2003.09.019
  24. Zhang et al. (2016) A novel aluminum-graphite dual-ion battery 6(11) https://doi.org/10.1002/aenm.201502588
  25. Ji et al. (2017) A novel potassium-ion-based dual-ion battery 29(19) https://doi.org/10.1002/adma.201700519
  26. Mu et al. (2021) Molecular grafting towards high-fraction active nanodots implanted in N-doped carbon for sodium dual-ion batteries 8(7)
  27. Zhu et al. (2021) Porous N-doped carbon/MnO2 nanoneedles for high performance ionic liquid-based supercapacitors https://doi.org/10.1016/j.matlet.2021.129837
  28. Liu et al. (2021) Towards applicable photoacoustic micro-fluidic pumps: tunable excitation wavelength and improved stability by fabrication of Ag-Au alloying nanoparticles https://doi.org/10.1016/j.jallcom.2021.161091
  29. Liu et al. (2021) Ultrasensitive exhaled breath sensors based on anti-resonant hollow core fiber with in situ grown ZnO-Bi2O3 nanosheets 8(6) https://doi.org/10.1002/admi.202001978
  30. Guo et al. (2018) Multi-functional hydroxyapatite/polyvinyl alcohol composite aerogels with self-cleaning, superior fire resistance and low thermal conductivity (pp. 128-136) https://doi.org/10.1016/j.compscitech.2018.01.020
  31. Brazdis et al. (2021) Recent progress in the application of hydroxyapatite for the adsorption of heavy metals 14(22) https://doi.org/10.3390/ma14226898
  32. Ibrahim et al. (2020) Hydroxyapatite, a multifunctional material for air water and soil pollution control: a review https://doi.org/10.1016/j.jhazmat.2019.121139
  33. Zhang et al. (2017) Biocompatible, ultralight, strong hydroxyapatite networks based on hydroxyapatite microtubes with excellent permeability and ultralow thermal conductivity 9(9) (pp. 7918-7928) https://doi.org/10.1021/acsami.6b13328
  34. Quilitz et al. (2010) Effect of the Ca/P ratio on the dielectric properties of nanoscaled substoichiometric hydroxyapatite (pp. 399-405) https://doi.org/10.1007/s10856-009-3875-1
  35. Xu et al. (2016) Influence of curing accelerators on the imidization of polyamic acids and properties of polyimide films 31(5) (pp. 1137-1143) https://doi.org/10.1007/s11595-016-1502-9
  36. Hu et al. (2010) One-step modification of nano-hydroxyapatite coating on titanium surface by hydrothermal method (pp. 2000-2006) https://doi.org/10.1016/j.surfcoat.2010.08.088
  37. Schander et al. (2021) Towards long-term stable polyimide-based flexible electrical insulation for chronically implanted neural electrodes 12(11) https://doi.org/10.3390/mi12111279
  38. Rial et al. (2021) Advanced materials based on nanosized hydroxyapatite 26(11) https://doi.org/10.3390/molecules26113190
  39. Slack (1964) Platinum as a thermal conductivity standard 35(2) (pp. 339-344) https://doi.org/10.1063/1.1713313
  40. Yang et al. (2008) Solvothermal synthesis and characterization of Ln (Eu3+, Tb3+) doped hydroxyapatite 328(1) (pp. 203-210) https://doi.org/10.1016/j.jcis.2008.09.010
  41. Hashizume et al. (2013) Biomimetic calcium phosphate coating on polyimide films by utilizing surface-selective hydrolysis treatments 121(1417) (pp. 816-818) https://doi.org/10.2109/jcersj2.121.816
  42. Hong and Lieber (2019) Novel electrode technologies for neural recordings 20(6) (pp. 330-345) https://doi.org/10.1038/s41583-019-0140-6
  43. Gross et al. (1998) Amorphous phase formation in plasma-sprayed hydroxyapatite coatings 39(30) (pp. 407-414) https://doi.org/10.1002/(SICI)1097-4636(19980305)39:3<407::AID-JBM9>3.0.CO;2-N
  44. Lu et al. (2003) Factors influencing phase compositions and structure of plasma sprayed hydroxyapatite coatings during heat treatment 206(1–4) (pp. 345-354) https://doi.org/10.1016/S0169-4332(02)01308-9
  45. Grill et al. (2009) Implanted neural interfaces: biochallenges and engineered solutions (pp. 1-24) https://doi.org/10.1146/annurev-bioeng-061008-124927
  46. Wurth et al. (2017) Long-term usability and bio-intergration of polyimide-based intra-neural stimulating electrodes (pp. 114-129) https://doi.org/10.1016/j.biomaterials.2017.01.014