10.1007/s40095-015-0168-y

Exergy analysis of a solar combined cycle: organic Rankine cycle and absorption cooling system

  1. University of Paris Ouest Nanterre La Défense, Ville d’Avray, 92 410, FR
  2. University of Paris Ouest Nanterre La Défense, Ville d’Avray, 92 410, FR University of Politehnica Bucharest, Bucharest, 060042, RO
  3. University of Politehnica Bucharest, Bucharest, 060042, RO
Cover Image

Published in Issue 2015-03-19

How to Cite

Grosu, L., Marin, A., Dobrovicescu, A., & Queiros-Conde, D. (2015). Exergy analysis of a solar combined cycle: organic Rankine cycle and absorption cooling system. International Journal of Energy and Environmental Engineering, 7(4 (December 2016). https://doi.org/10.1007/s40095-015-0168-y

HTML views: 57

PDF views: 138

Abstract

Abstract In this paper, exergy analysis is used to evaluate the performance of a combined cycle: organic Rankine cycle (ORC) and absorption cooling system (ACS) using LiBr–H 2 O, powered by a solar field with linear concentrators. The goal of this work is to design the cogeneration system able to supply electricity and ambient cooling of an academic building and to find solutions to improve the performance of the global system. Solar ACS is combined with the ORC system—its coefficient of performance depends on the inlet temperature of the generator which is imposed by the outlet of the ORC. Exergetic efficiency and exergy destruction ratio are calculated for the whole system according to the second law of thermodynamics. Exergy analysis of each sub-system leads to the choice of the optimum physical parameters for minimum local exergy destruction ratios. In this way, a different connection of the heat exchangers is proposed in order to assure a maximum heat recovery.

Keywords

  • ORC,
  • Organic Rankine cycle,
  • Absorption system,
  • LiBr–H2O,
  • Solar energy,
  • Exergy analysis

References

  1. Martaj et al. (2006) Exergetical analysis and design optimization of the Stirling engine 3(1) (pp. 45-67) https://doi.org/10.1504/IJEX.2006.008325
  2. Wardono, B.: Simulation of a Solar-Assisted LiBr–H2O Cooling System. Iowa State University, Ames (1994)
  3. Nelson, R.M., Wardono, B.: Simulation of a solar-assisted LiBr–H
  4. 2
  5. O cooling system. ASHRAE Trans., 102–104 (1996)
  6. Grosu et al. (2004) Study of improvement of the performance coefficient of machines operating with three reservoirs 1(1) (pp. 147-162) https://doi.org/10.1504/IJEX.2004.004729
  7. Untea et al. (2013) Energy and exergy analysis of an ejector refrigeration system 75(4) (pp. 111-126)
  8. Untea, A.: Schémas hybrides de production et distribution d’énergie thermique pour bâtiments. Ph.D. Thesis, University of Paris West/University of Politehnica, Bucharest (2013)
  9. Ziegler, F.: State of the art in absorption heat pumping and cooling technologies. Int. J. Refrig.
  10. 25(
  11. , 450–459 (2002)
  12. Chen, H., Goswam, D.Y., Stefanakos, E.K.: A review of thermodynamic cycle and working fluids for the conversion of low-grade heat. Renew. Sustain. Energy Rev. 3059–3067 (2010)
  13. Dai, Y., Wang, J., Gao, L.: Parametric optimization and comparative study of organic Rankine cycle (ORC) for low grade waste heat recovery. Energy Convers. Manag. 576–582 (2009)
  14. Wang et al. (2010) Performance evaluation of a low-temperature solar Rankine cycle system utilizing R245fa (pp. 353-364) https://doi.org/10.1016/j.solener.2009.11.004
  15. Guo, T., Wang, H.X., Jhang, S.J.: Selection of working fluids for a novel low-temperature geothermally powered ORC based cogeneration system. Energy Convers. Manag. 946–952 (2011)
  16. Marin, A., Untea, A., Grosu, L., Dobrovicescu, A.: Parametric and exergy analysis of a combined cooling and power organic Rankine cycle. In: Microgen II: Proceedings of the 3rd edition of the International Conference on Microgeneration and Related Technologies, Italy (2013)
  17. Grosu, L., Ribeiro, P., Lagouardat, A., Uhlmann, A.: Evaluation des performances et optimisation de la centrale solaire. In: Rapport de contrat MICROSOL (2014)
  18. Kilic and Kaynakli (2007) Second law based thermodynamic analysis of water lithium bromide absorption refrigeration system 32(8) (pp. 1505-1512) https://doi.org/10.1016/j.energy.2006.09.003
  19. Kaushik, S.C., Arora, A.: Energy and exergy analysis of single effect and series flow double effect water–lithium bromide absorption refrigeration systems. Int. J. Refrig.
  20. 33
  21. (6), 1247–1258 (2009)
  22. González-Gil, A., Izquierdo, M., Marcos, J.D., Palacios, E.: Experimental evaluation of a direct aircooled lithium bromide–water absorption prototype for solar air conditioning. Appl. Therm. Eng.
  23. 31
  24. (16), 3358–3368 (2011)
  25. Sencan, A., Kemal, A., Soteris, A.: Exergy analysis of lithium bromide/water absorption systems. Renew. Energy
  26. 30
  27. (5), 645–657 (2005)
  28. Grosu et al. (2014) Energy and exergy analyses of a solar driven absorption cooling system 15(3) (pp. 308-327) https://doi.org/10.1504/IJEX.2014.065706
  29. Aphornratana, S., Sriveerakul, T.: Experimental studies of a single-effect absorption refrigerator using aqueous lithium–bromide: effect of operating condition to system performance. Exp. Therm. Fluid Sci.
  30. 33
  31. (2), 658–669 (2007)
  32. Zadeh, F.P., Bozorgan, N.: The energy and exergy analysis of a single effect absorption chiller. Int. J. Adv. Des. Manuf. Technol.
  33. 4
  34. (4), 19–26 (2011)
  35. Bejan (1996) CRC Press
  36. Bejan et al. (1996) Wiley
  37. Benelmir and Grosu (2001) Exergy versus entropy analysis—illustration with a refrigerating machine 11(1) (pp. 15-30)
  38. Dobrovicescu, A.: Principiile Analizei Exergoeconomice. Politehnica Press, Bucharest (2007)
  39. Grosu (2012) Rapport HDR, University of Paris West