Investigating the effects of nanorefrigerants in a cascaded vapor compression refrigeration cycle
- Department of Environmental Science, Cyprus International University, Nicosia, Mersin 10, TR
- Department of Energy Systems, Cyprus Internatonal University, Nicosia, Mersin 10, TR
- Department of Energy Systems Engineering, Faculty of Integrated Technologies, Universiti Brunei Darussalam, Bandar Seri Begawan, BN
- Department of Environmental Science, Cyprus International University, Nicosia, Mersin 10, TR Department of Bioengineering, Cyprus International University, Nicosia, Mersin 10, TR
Published in Issue 2022-09-29
How to Cite
Akhayere, E., Adebayo, V., Adedeji, M., Abid, M., Kavaz, D., & Dagbasi, M. (2022). Investigating the effects of nanorefrigerants in a cascaded vapor compression refrigeration cycle. International Journal of Energy and Environmental Engineering, 14(4 (December 2023). https://doi.org/10.1007/s40095-022-00537-x
Abstract
Abstract It is vital, following the Kyoto Protocol, to find environmentally benign and energy-efficient refrigerants, consequently boosting the coefficient of performance (COP). Refrigeration systems are used extensively in the industrial, home, and commercial sectors for cooling, heating, food preservation, and cryogenic purposes. Researchers have successfully employed the application of nanoparticles in cooling systems to achieve improved enhancement, reliability, and efficiency of refrigeration systems because of their higher heat transfer and thermophysical capabilities. The function of numerous variables, however, makes the experimental technique appear to be costly and time-consuming to carry out. This study was, therefore, designed to numerically simulate the performance assessment of a nanoparticle-enhanced Cascaded Vapor Compression Refrigeration Cycle (CVCRC). The focus of this paper is on four distinct SiO 2 nanoparticle nanorefrigerants and their pure fluids: two HFCs as well as two fourth-generation refrigerants (HFOs), namely; R12, R134a, R1234yf, and R-1234ze (E). The results show that adding nanoparticles to the pure refrigerant improves COP, and the highest values were achieved with the R1234ze(E)/SiO2 mixture. Increasing the mass concentration of the nanoparticles leads to an increase in the refrigeration effect, an increase in COP, and a reduction in compressor work. Although R125 had the lowest compressor work of 47.12 kW when SiO2 nanoparticles are introduced, however, is not suitable for refrigeration because of its high GWP values. R1234ze has the second-lowest compressor work of 59.58 kW with the addition of SiO 2 , it is consequently more energy efficient and can be used in its place as it has a GWP of 6, among other benefits.Keywords
- Nanorefrigerants,
- COP,
- Refrigeration,
- Cascaded vapor compression refrigeration cycle,
- Compressor work
References
- Mahbubul et al. (2013) Influence of particle concentration and temperature on thermal conductivity and viscosity of Al2O3/R141b nanorefrigerant (pp. 100-104) https://doi.org/10.1016/j.icheatmasstransfer.2013.02.004
- Adebayo et al. (2020) Comparative thermodynamic performance analysis of a cascade refrigeration system with new refrigerants paired with CO2 https://doi.org/10.1016/j.applthermaleng.2020.116286
- Kumar (2020) Comparative analysis of cascade refrigeration system based on energy and exergy using different refrigerant Pairs 6(1) (pp. 106-116) https://doi.org/10.18186/thermal.671652
- Sanukrishna and Vishnu (2017) Nanorefrigerants for energy efficient refrigeration systems 31(8) (pp. 3993-4001) https://doi.org/10.1007/s12206-017-0746-4
- Aktas et al. (2015) A theoretical comparative study on nanorefrigerant performance in a single-stage vapor-compression refrigeration cycle 7(1) https://doi.org/10.1155/2014/138725
- Celen et al. (2014) A review of nanorefrigerants: flow characteristics and applications (pp. 125-140) https://doi.org/10.1016/j.ijrefrig.2014.05.009
- Fang et al. (2015) A review of flow boiling heat transfer of nanofluids (pp. 1003-1017) https://doi.org/10.1016/j.applthermaleng.2015.08.100
- Sun and Yang (2014) Flow boiling heat transfer characteristics of nano-refrigerants in a horizontal tube (pp. 206-214) https://doi.org/10.1016/j.ijrefrig.2013.08.020
- Alawi et al. (2015) Nanorefrigerant effects in heat transfer performance and energy consumption reduction: a review (pp. 76-83) https://doi.org/10.1016/j.icheatmasstransfer.2015.10.009
- Gupta et al. (2018) Thermodynamic analysis and effects of replacing HFC by fourth-generation refrigerants in VCR systems 26(02) https://doi.org/10.1142/S201013251850013X
- Perkins, J.: Apparatus for producing ice and cooling fluids. Br. Pat., no. 6662, 1834
- Nagengast, B.A.: A history of refrigerants. CFCs Time Transit. (1989)
- de Chazournes, L.B.: Kyoto protocol to the united nations framework convention on climate change. UN’s Audiov. Libr. Int. Law (http//untreaty. un. org/cod/avl/ha/kpccc/kpccc. html). (1998)
- Montzka et al. (2009) Accelerated increases observed for hydrochlorofluorocarbons since 2004 in the global atmosphere https://doi.org/10.1029/2008GL036475
- Fluorochemicals, D.: DuPont fluorochemicals develops next generation refrigerants–new sustainable alternatives would offer practical solutions. Press Release. Wilmington, DE, USA (09.02. 06). (2006)
- Kasaeian et al. (2018) Applications of eco-friendly refrigerants and nanorefrigerants: a review (pp. 91-99) https://doi.org/10.1016/j.rser.2018.07.033
- Subramani and Prakash (2011) Experimental studies on a vapour compression system using nanorefrigerants 3(9) (pp. 95-102) https://doi.org/10.4314/ijest.v3i9.8
- Jwo et al. (2009) Effects of nanolubricant on performance of hydrocarbon refrigerant system 27(3) (pp. 1473-1477)
- Peng et al. (2009) Measurement and correlation of frictional pressure drop of refrigerant-based nanofluid flow boiling inside a horizontal smooth tube 32(7) (pp. 1756-1764) https://doi.org/10.1016/j.ijrefrig.2009.06.005
- Kedzierski (2009) Effect of CuO nanoparticle concentration on R134a/lubricant pool-boiling heat transfer https://doi.org/10.1115/1.3072926
- Bi et al. (2008) Application of nanoparticles in domestic refrigerators 28(14–15) (pp. 1834-1843) https://doi.org/10.1016/j.applthermaleng.2007.11.018
- Sabareesh et al. (2012) Application of TiO2 nanoparticles as a lubricant-additive for vapor compression refrigeration systems–an experimental investigation 35(7) (pp. 1989-1996) https://doi.org/10.1016/j.ijrefrig.2012.07.002
- Javadi and Saidur (2013) Energetic, economic and environmental impacts of using nanorefrigerant in domestic refrigerators in Malaysia (pp. 335-339) https://doi.org/10.1016/j.enconman.2013.05.013
- Wang, R. X., Hao, B., Xie, G.Z., Li, H.Q.: A refrigerating system using HFC134a and mineral lubricant appended with n-TiO2 (R) as working fluids. In: Proceedings of the 4th International Symposium on HAVC, Tsinghua University Press, Beijing, China, 2003, pp. 888–892
- Li et al. (2008) Investigation of Pool boiling heat transfer of R11 with TiO~ 2 nano-particles 29(1)
- Mahbubul et al. (2015) Thermal performance analysis of Al2O3/R-134a nanorefrigerant (pp. 1034-1040) https://doi.org/10.1016/j.ijheatmasstransfer.2015.02.038
- Kumar and Elansezhian (2014) ZnO nanorefrigerant in R152a refrigeration system for energy conservation and green environment 9(1) (pp. 75-80) https://doi.org/10.1007/s11465-014-0285-y
- Kumar et al. (2016) A performance study of vapour compression refrigeration system using ZrO2 nano particle with R134a and R152a” (pp. 410-421)
- Coumaressin and Palaniradja (2018) Experimental Analysis of a Refrigeration system using Al2O3/CuO/TiO2/ZnO-R1234yf Nanofluids as refrigerant 4(08) (pp. 69-75)
- Bhattacharya and Mandal (2018) Synthesis of rice straw extracted nano-silica-composite membrane for CO2 separation (pp. 241-252) https://doi.org/10.1016/j.jclepro.2018.03.099
- Essien and Kavaz (2019) Effective and reusable nano-silica synthesized from barley and wheat grass for the removal of nickel from agricultural wastewater 26(25) (pp. 25802-25813) https://doi.org/10.1007/s11356-019-05759-x
- Akhayere et al. (2020) Novel magnetic nano silica synthesis using barley husk waste for removing petroleum from polluted water for environmental sustainability 12(24) (pp. 1-16) https://doi.org/10.3390/su122410646
- Handbook, A.: ASHRAE handbook–fundamentals. Atlanta, GA. (2009)
- McLinden, M.J.O., Thol, M., Lemmon, E.W.: Thermodynamic properties of trans-1, 3, 3, 3-tetrafluoropropene [R1234ze (E)]: measurements of density and vapor pressure and a comprehensive equation of state. (2010)
- Steven Brown, P.E.J.: Methodology for estimating thermodynamic parameters and performance of alternative refrigerants. ASHRAE Trans.
- 114
- : 230 (2008)
- Steven Brown (2009) HFOs: new, low global warming potential refrigerants 51(8)
- Di Nicola et al. (2010) P− V− T Behavior of 2, 3, 3, 3-Tetrafluoroprop-1-ene (HFO-1234yf) in the vapor phase from (243 to 373) K 55(9) (pp. 3302-3306) https://doi.org/10.1021/je100102q
- Del Col et al. (2010) Heat transfer and pressure drop during condensation of the low GWP refrigerant R1234yf 33(7) (pp. 1307-1318) https://doi.org/10.1016/j.ijrefrig.2010.07.020
- Xuan and Roetzel (2000) Conceptions for heat transfer correlation of nanofluids 43(19) (pp. 3701-3707) https://doi.org/10.1016/S0017-9310(99)00369-5
- Hussin et al. (2022) Experimental performance of R134a/SiO2 in refrigeration system for domestic use 95(1) (pp. 145-163) https://doi.org/10.37934/arfmts.95.1.145163
- Krishnan et al. (2017) Performance analysis of a nano refrigerant mixtures in a domestic refrigeration system 11(6) (pp. 508-516)
- Odunfa and Oseni (2021) Numerical simulation and performance assessment of a nanoparticle enhanced vapour compression refrigeration system 9(11) (pp. 33-49) https://doi.org/10.4236/jpee.2021.911002
10.1007/s40095-022-00537-x