<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
<PublisherName>OICC Press</PublisherName>
<JournalTitle>Signal Processing and Renewable Energy (SPRE)</JournalTitle>
<Issn>2588-7335</Issn>
<Volume>5</Volume>
<Issue>3</Issue>
<PubDate PubStatus="epublish">
<Year>2021</Year>
<Month>09</Month>
<Day>01</Day>
</PubDate>
</Journal>
<ArticleTitle>Switching Pattern for Transformer Cascaded Inverter in Dynamic Voltage Restorer Structure</ArticleTitle>
<VernacularTitle></VernacularTitle>
<FirstPage>51</FirstPage>
<LastPage>65</LastPage>
<ELocationID EIdType="doi"></ELocationID>
<Language>EN</Language>
<AuthorList>
<Author>
<FirstName>Shirin</FirstName>
<LastName>Soltani</LastName>
<Affiliation>Department of Electrical Engineering, Dehagh Branch, Islamic Azad University, 
Dehagh, Isfahan, Iran</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>Majid</FirstName>
<LastName>Dehghani</LastName>
<Affiliation>Smart Microgrid Research Center, Najafabad Branch, Islamic Azad University,  Najafabad, Iran</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>Majid</FirstName>
<LastName>Moazzami</LastName>
<Affiliation>Department of Electrical Engineering, Najafabad Branch, Islamic Azad University,
 Naein, Iran</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
</AuthorList>
<PublicationType>Journal Article</PublicationType>
<History>
<PubDate PubStatus="received">
<Year>2021</Year>
<Month>09</Month>
<Day>01</Day>
</PubDate>
</History>
<Abstract>Sensitive loads cannot tolerate voltage sags and swells in power distribution networks and lots of problems are engendered for them. Therefore, dif f e  rent instruments are pla nn ed to compensate volt a ge swells and sags. Between them dynamic voltage restorer (DVR) has found special import a n c e, because it operates better than others for this purpose and restores voltage to its initial value conveniently. A DVR is a power-electronic controller that can protect sensitive loads from disturbances in the supply system. The DVR is installed in series to the network. In this paper 9 level cascaded inverters with cas ca d ed transfor m e r s are used in DVR internal circuit, but the difference in magnetic flux in cascading transformers has adverse effects on the plan. Therefore, a new switching pattern is used</Abstract>
</Article>
</ArticleSet>