<ArticleTitle>A Digital Ground Distance Relaying Algorithm to Reduce the Effect of Fault Resistance during Single Phase to Ground and Simultaneous Faults</ArticleTitle>
<VernacularTitle></VernacularTitle>
<FirstPage></FirstPage>
<LastPage></LastPage>
<ELocationID EIdType="doi"></ELocationID>
<Language>EN</Language>
<AuthorList>
<Author>
<FirstName>Mohammad</FirstName>
<LastName>Razaz</LastName>
<Affiliation>Department of Electrical Engineering, Shahid Chamran University of Ahvaz, Iran</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>Seyyed Ghodratollah</FirstName>
<LastName>Seifossadat</LastName>
<Affiliation>Department of Electrical Engineering, Shahid Chamran University of Ahvaz, Iran</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>Morteza</FirstName>
<LastName>Razaz</LastName>
<Affiliation>Department of Electrical Engineering, Shahid Chamran University of Ahvaz, Iran</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>Mahmood</FirstName>
<LastName>Joorabian</LastName>
<Affiliation>Department of Electrical Engineering, Shahid Chamran University, Ahvaz, Iran</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
</AuthorList>
<PublicationType>Journal Article</PublicationType>
<History>
<PubDate PubStatus="received">
<Year>2024</Year>
<Month>02</Month>
<Day>20</Day>
</PubDate>
</History>
<Abstract>This paper intends to provide an algorithm of fault resistance compensation for digital ground distance relay considering the voltage and current transformer effects. Performance of the conventional ground distance relaying manner is adversely affected by different ground faults and also typical type, called a simultaneous open conductor and ground fault. The proposed scheme by using local-end data only, has shown satisfactory performances under wide variations in fault location, with different values of fault resistance and having positive and negative of power transfer angle. The presented method which has been carried out on the IEEE 14 bus benchmark is executed in PSCAD/EMTDC and MATLAB software and the results show the accurate performance of mention configuration.</Abstract>
<ObjectList>
<Object Type="keyword">
<Param Name="value">Digital Ground Distance Relaying</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Fault Resistance Compensation</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Simultaneous Open Conductor and Ground Fault</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Single Phase to Ground Fault</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Voltage and Current Transformer</Param>
</Object>
</ObjectList>
</Article>
</ArticleSet>