<ArticleTitle>Investigation of Stator Windings Looseness of Polyphase Induction Machine after Rewinded in Workshop: Numerical and Experimental Analysis</ArticleTitle>
<VernacularTitle></VernacularTitle>
<FirstPage></FirstPage>
<LastPage></LastPage>
<ELocationID EIdType="doi">10.30486/mjee.2022.696514</ELocationID>
<Language>EN</Language>
<AuthorList>
<Author>
<FirstName>V Sri Ram Prasad</FirstName>
<LastName>Kapu</LastName>
<Affiliation>National Institute of Technology Raipur</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>Varsha</FirstName>
<LastName>Singh</LastName>
<Affiliation>National Institute of Technology Raipur</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
</AuthorList>
<PublicationType>Journal Article</PublicationType>
<History>
<PubDate PubStatus="received">
<Year>2022</Year>
<Month>12</Month>
<Day>15</Day>
</PubDate>
</History>
<Abstract>Electric machines, particularly induction motors, are widely used in industry as they are robust in construction and require less maintenance. These machines are continuously operated under high loading conditions, which may result in machine vibrations. The Experimental-Modal-Analysis (EMA) technique is employed in this research to determine electrical machine vibrations. The hammer test is a popular EMA approach for locating the exact location of winding looseness. EMA test is executed on the stator winding to extract the modal parameters to find exact deformation in machine windings. Mathematical calculations and a numerical model are developed to validate the experimental data. The EMAâs Operational Deformation Structure (ODS) validates the windingâs looseness precisely. Two test machinesâ MA and MB windings are tested with EMA to evaluate the stator slot structureâs looseness. Finally, the proposed technique is compared with the finite element technique along with mathematical calculations for verification.</Abstract>
<ObjectList>
<Object Type="keyword">
<Param Name="value">Finite-Element-Method. Experimental-Modal-Analysis</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Induction Machine</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Machine-A (MA)</Param>