<ArticleTitle>Four-Leg VSI Based DSTATCOM for Compensating Nonlinear and Unbalanced Loads</ArticleTitle>
<VernacularTitle></VernacularTitle>
<FirstPage></FirstPage>
<LastPage></LastPage>
<ELocationID EIdType="doi"></ELocationID>
<Language>EN</Language>
<AuthorList>
<Author>
<FirstName>S. R.</FirstName>
<LastName>Reddy</LastName>
<Affiliation>Department of Electrical Engineering,GNITC, Ibrahimpatnam, Hyderabad, India</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>P. V.</FirstName>
<LastName>Prasad</LastName>
<Affiliation>Department of Electrical Engineering,CBIT, Gandipet, Hyderabad, India</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>G.N.</FirstName>
<LastName>Srinivas</LastName>
<Affiliation>Department of Electrical Engineering, JNTUCH, Hyderabad, India</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
</AuthorList>
<PublicationType>Journal Article</PublicationType>
<History>
<PubDate PubStatus="received">
<Year>2024</Year>
<Month>02</Month>
<Day>15</Day>
</PubDate>
</History>
<Abstract>This paper presents a study on the four-leg VSI based distribution static compensator (D-STATCOM) for compensation of neutral, source &amp; PCC current harmonic distortion, PCC voltage regulation and compensation of unbalanced in current waveform. This solution could be used for three-phase four-wire nonlinear and unbalanced load medium voltage distribution system. The proposed control algorithm is developed based on synchronous reference frame theory with the PI controller. The obtained reference current signal from control algorithm is compared in hysteresis band current controller for a better switching of the D-STATCOM. The performance of the system with implementing the D-STATCOM is also analyzed and compared. The proposed control method is implemented on 11/0.4kv medium voltage distribution system and provided effective compensation for reactive power and harmonic distortion mitigation. The simulation results are obtained using MATLAB/SIMULINK.</Abstract>
<ObjectList>
<Object Type="keyword">
<Param Name="value">Distribution static compensator (D-STATCOM)</Param>
</Object>
<Object Type="keyword">
<Param Name="value">hysteresis current controller. Harmonic Distortion</Param>
</Object>
<Object Type="keyword">
<Param Name="value">PI controller</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Synchronous reference frame (SRF) theory</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Voltage Source Inverter VSI</Param>
</Object>
</ObjectList>
</Article>
</ArticleSet>