<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
<PublisherName>OICC Press</PublisherName>
<JournalTitle>Majlesi Journal of Electrical Engineering</JournalTitle>
<Issn>2345-3796</Issn>
<Volume>11</Volume>
<Issue>4</Issue>
<PubDate PubStatus="epublish">
<Year>2024</Year>
<Month>02</Month>
<Day>18</Day>
</PubDate>
</Journal>
<ArticleTitle>A Novel High Sensitivity MEMS Acoustic Sensor using Corrugated Diaphragm</ArticleTitle>
<VernacularTitle></VernacularTitle>
<FirstPage></FirstPage>
<LastPage></LastPage>
<ELocationID EIdType="doi"></ELocationID>
<Language>EN</Language>
<AuthorList>
<Author>
<FirstName>Bahram</FirstName>
<LastName>Azizollah Ganji</LastName>
<Affiliation>Department of Electrical and Computer Engineering, Babol University of Technology, Babol</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>Mehdi</FirstName>
<LastName>Taybi</LastName>
<Affiliation>Department of Electrical and Computer Engineering, Babol University of Technology, Babol, Iran</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
</AuthorList>
<PublicationType>Journal Article</PublicationType>
<History>
<PubDate PubStatus="received">
<Year>2024</Year>
<Month>02</Month>
<Day>18</Day>
</PubDate>
</History>
<Abstract>In this paper we presented a novel MEMS acoustic sensor using corrugated diaphragm. The corrugated diaphragm is used to decrease the effect of residual stress and thus improve the sensitivity of micromachined acoustic sensor. The displacement and mechanical sensitivity of flat and corrugated diaphragms, and also open-circuit sensitivity and pull-in voltage of sensors are calculated using MATLAB and simulated using FEM (finite element method). The results show that the displacement and mechanical sensitivity of corrugated diaphragm are bigger than the flat one. The pull-in voltage of corrugated sensor is smaller and the open-circuit sensitivity is much higher than the sensor with flat diaphragm. The results also show that the analytical model is very close with FEM simulation results.</Abstract>
<ObjectList>
<Object Type="keyword">
<Param Name="value">MEMS</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Acoustic sensor</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Corrugated diaphragm</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Stress</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Sensitivity</Param>
</Object>
</ObjectList>