<ArticleTitle>Design of Fuzzy FOPID Controller Optimized by ICA for Control of AVR</ArticleTitle>
<VernacularTitle></VernacularTitle>
<FirstPage></FirstPage>
<LastPage></LastPage>
<ELocationID EIdType="doi"></ELocationID>
<Language>EN</Language>
<AuthorList>
<Author>
<FirstName>Saber</FirstName>
<LastName>Falahati Aliabadi</LastName>
<Affiliation>Department of Electrical and Computer Engineering, University of Kashan, Kashan, Iran</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>Seyyd Abbas</FirstName>
<LastName>Taher</LastName>
<Affiliation>Electrical and Computer Engineering Department, University of Kashan, Kashan, Iran</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
</AuthorList>
<PublicationType>Journal Article</PublicationType>
<History>
<PubDate PubStatus="received">
<Year>2024</Year>
<Month>02</Month>
<Day>18</Day>
</PubDate>
</History>
<Abstract>In this paper Fuzzy-FOPID controller is used in order to control automatic voltage regulator (AVR) system. This controller has six parameters. In this paper, optimization method is employed to determine the controller parameters. For this purpose, imperialist competitive algorithm (ICA) is used for its high accuracy and good performance. To illustrate performance of proposed controller, some simulations are carried out in MATALB and the results are compared with FOPID controller results. Good performance of proposed controller is validated by results of the simulations.</Abstract>
<ObjectList>
<Object Type="keyword">
<Param Name="value">LDMOS transistor</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Current operating point</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Threshold voltage</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Cut-off Frequency</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Transconductance</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Breakdown voltage</Param>
</Object>
</ObjectList>
</Article>
</ArticleSet>