<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
<PublisherName>OICC Press</PublisherName>
<JournalTitle>Journal of Theoretical and Applied Physics</JournalTitle>
<Issn>2251-7235</Issn>
<Volume>6</Volume>
<Issue>1</Issue>
<PubDate PubStatus="epublish">
<Year>2023</Year>
<Month>11</Month>
<Day>17</Day>
</PubDate>
</Journal>
<ArticleTitle>Fast and thermal neutron radiographies based on a compact neutron generator</ArticleTitle>
<VernacularTitle></VernacularTitle>
<FirstPage></FirstPage>
<LastPage></LastPage>
<ELocationID EIdType="doi">10.1186/2251-7235-6-20</ELocationID>
<Language>EN</Language>
<AuthorList>
<Author>
<FirstName>Jacob G</FirstName>
<LastName>Fantidis</LastName>
<Affiliation>Department of Electrical Engineering, Kavala Institute of Technology</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>Bandekas V</FirstName>
<LastName>Dimitrios</LastName>
<Affiliation>Department of Electrical Engineering, Kavala Institute of Technology</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>Potolias</FirstName>
<LastName>Constantinos</LastName>
<Affiliation>Department of Electrical Engineering, Kavala Institute of Technology</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
<Author>
<FirstName>Vordos</FirstName>
<LastName>Nick</LastName>
<Affiliation>Department of Electrical Engineering, Kavala Institute of Technology</Affiliation>
<Identifier Source="ORCID"></Identifier>
</Author>
</AuthorList>
<PublicationType>Journal Article</PublicationType>
<History>
<PubDate PubStatus="received">
<Year>2023</Year>
<Month>11</Month>
<Day>17</Day>
</PubDate>
</History>
<Abstract>AbstractFast neutrons that are produced via compact neutron generators have been used for thermal and fast neutron radiographies. In order to investigate objects with different sizes and produce radiographs of variable qualities, the proposed facility has been considered with a wide range of values for the parameters characterizing the thermal and fast neutron radiographies. The proposed system is designed according to article 4 of the Restriction of Hazardous Substances Directive 2002/95/EC, hence, excluded the use of cadmium and lead, and has been simulated using the MCNP4B code. The Monte Carlo calculations were carried out using three different neutron sources: deuterium-deuterium, deuterium-tritium, and tritium-tritium neutron generators.</Abstract>
<ObjectList>
<Object Type="keyword">
<Param Name="value">21.60.Ka</Param>
</Object>
<Object Type="keyword">
<Param Name="value">24.10.Lx</Param>
</Object>
<Object Type="keyword">
<Param Name="value">28.20.Pr</Param>
</Object>
<Object Type="keyword">
<Param Name="value">29.25.Dz</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Compact neutron generator</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Fast neutron radiography</Param>
</Object>
<Object Type="keyword">
<Param Name="value">MCNP4B</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Restriction of hazardous substances directive</Param>
</Object>
<Object Type="keyword">
<Param Name="value">Thermal neutron radiography</Param>
</Object>
</ObjectList>
</Article>
</ArticleSet>